Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add filters








Year range
1.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 664-667, 2019.
Article in Chinese | WPRIM | ID: wpr-801354

ABSTRACT

Objective@#To summarize the experience of surgical treatment of 18 cases of severe aortic stenosis with ventricular septum hypertrophy.@*Methods@#Clinical data of 18 patients with severe aortic stenosis admitted to the first affiliated hospital of zhengzhou university from January 2013 to December 2016 were collected. There were 7 males and 11 females. The mean age was (50.4±4.2) years old. All patients were diagnosed with severe stenosis of main artery valve by echocardiography before surgery, with mean aortic valve orifice area (0.57±0.11) cm2, cardiac function (NYHA classification) grade Ⅱ in 4 patients, grade Ⅲ in 9 patients, and grade Ⅳ in 5 patients. There were 8 patients with mild aortic valve insufficiency, 4 patients with mild to moderate mitral valve insufficiency, 2 patients with moderate to severe aortic valve insufficiency, 3 patients with ascending aorta dilatation (ascending aorta inner diameter>4.5 cm), and 1 patient with atrial fibrillation. Interventricular septum thickness (15.82±2.04)mm, left ventricular posterior wall thickness (14.04±1.28)mm, ratio of interventricular septum thickness to left ventricular posterior wall thickness (IVS/LVPW) 1.12±0.91, inner diameter of left ventricular outflow tract (19.01±1.74)mm, cross-lobe differential pressure (102±8.40) mmHg (1 mmHg=0.133 kPa), left ventricular ejection fraction (LVEF) mean 0.49±0.05. Left ventricular end-diastolic diameter (LVEDD) (53.33±4.00) mm, left ventricular end-systolic diameter (LVESD) (27.11±1.99) mm, and left ventricular mass index (277.1±37.3) g/m2. All patients underwent aortic valve replacement (AVR) and partial interventricular septum resection under general anesthesia and conventional extracorporeal circulation, 2 patients underwent mitral valve formation (artificial valve ring), 2 patients underwent ascending aorta formation, and 1 patient underwent ascending aorta wrapping. During the operation, the time of extracorporeal circulation, aortic occlusion, number of defibrillation during the operation, type of valve implantation and postoperative complications were recorded. Regular follow-up was conducted to analyze the changes of various indexes at different preoperative and postoperative time.@*Results@#There was no death in the whole group. 2 patients were treated with temporary pacemakers. After drug treatment, sinus rhythm was restored on the 3rd and 6th day after surgery, and temporary pacemakers were removed. Echocardiography reexamination 1 week after the operation showed that all patients had a good artificial valve function and 2 patients had minor regurgitation of mitral valve. The difference in pressure across the valve, inner diameter of the left ventricular outflow tract, cardiac function classification, ventricular septum thickness, valve orifice area, and left ventricular mass index were significantly improved compared with the preoperative level (P<0.05). LVEF, LVEDD, and LVESD were compared with the preoperative level (P<0.05). After 6 months of follow-up, the difference in LVEF and LVEDD was statistically significant compared with the preoperative level (P<0.05).@*Conclusion@#Severe aortic stenosis combined with ventricular septum hypertrophy and partial ventricular septal muscle resection is a simple additional procedure in the AVR process, which does not increase the surgical risk and has a significant effect, and is conducive to postoperative left ventricular function recovery.

2.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 664-667, 2019.
Article in Chinese | WPRIM | ID: wpr-824868

ABSTRACT

Objective To summarize the experience of surgical treatment of 18 cases of severe aortic stenosis with ventricular septum hypertrophy.Methods Clinical data of 18 patients with severe aortic stenosis admitted to the first affiliated hospital of zhengzhou university from January 2013 to December 2016 were collected.There were 7 males and 11 females.The mean age was (50.4 ±4.2) years old.All patients were diagnosed with severe stenosis of main artery valve by echocardiography before surgery,with mean aortic valve orifice area (0.57 ±0.11) cm2,cardiac function (NYHA classification) grade Ⅱ in 4 patients,grade Ⅲ in 9 patients,and grade ⅣV in 5 patients.There were 8 patients with mild aortic valve insufficiency,4 patients with mild to moderate mitral valve insufficiency,2 patients with moderate to severe aortic valve insufficiency,3 patients with ascending aorta dilatation (ascending aorta inner diameter > 4.5 cm),and 1 patient with atrial fibrillation.Interventricular septum thickness (15.82 ± 2.04) mm,left ventricular posterior wall thickness (14.04 ± 1.28) mm,ratio of interventricular septum thickness to left ventricular posterior wall thickness (IVS/LVPW) 1.12 ±0.91,inner diameter of left ventricular outflow tract (19.01 ± 1.74) mm,cross-lobe differential pressure (102 ± 8.40) mmHg (1 mmHg =0.133 kPa),left ventricular ejection fraction (LVEF) mean 0.49 ± 0.05.Left ventricular end-diastolic diameter (LVEDD) (53.33 ± 4.00)mm,left ventricular end-systolic diameter (LVESD) (27.11 ± 1.99) mm,and left ventricular mass index (277.1 ± 37.3) g/m2.All patients underwent aortic valve replacement (AVR) and partial interventricular septum resection under general anesthesia and conventional extracorporeal circulation,2 patients underwent mitral valve formation (artificial valve ring),2 patients underwent ascending aorta formation,and 1 patient underwent ascending aorta wrapping.During the operation,the time of extracorporeal circulation,aortic occlusion,number of defibrillation during the operation,type of valve implantation and postoperative complications were recorded.Regular follow-up was conducted to analyze the changes of various indexes at different preoperative and postoperative time.Results There was no death in the whole group.2 patients were treated with temporary pacemakers.After drug treatment,sinus rhythm was restored on the 3rd and 6th day after surgery,and temporary pacemakers were removed.Echocardiography reexamination 1 week after the operation showed that all patients had a good artificial valve function and 2 patients had minor regurgitation of mitral valve.The difference in pressure across the valve,inner diameter of the left ventricular outflow tract,cardiac function classification,ventricular septum thickness,valve orifice area,and left ventricular mass index were significantly improved compared with the preoperative level (P < 0.05).LVEF,LVEDD,and LVESD were compared with the preoperative level (P < 0.05).After 6 months of follow-up,the difference in LVEF and LVEDD was statistically significant compared with the preoperative level (P < 0.05).Conclusion Severe aortic stenosis combined with ventricular septum hypertrophy and partial ventricular septal muscle resection is a simple additional procedure in the AVR process,which does not increase the surgical risk and has a significant effect,and is conducive to postoperative left ventricular function recovery.

3.
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care ; (6): 594-598, 2018.
Article in Chinese | WPRIM | ID: wpr-734120

ABSTRACT

Objective To evaluate the efficacy and safety of oprinon hydrochloride in increasing cardiac pump function and stabilizing hemodynamics and preventing common complications after cardiac valve replacement. Methods Sixty-two patients were admitted to the First Affiliated Hospital of Zhengzhou University from January to August 2018 to undergo cardiac valve replacement operation, post-operatively, 32 patients using oprinon hydrochloride were in the observation group and 30 patients using milrinone were in the control group. Both groups received basic treatment, additionally the observation group was given oprinon hydrochloride intravenous pump injection for 48 hours and the control group was given milrinone intravenous pump injection for 48 hours. The changes of vital signs (blood pressure, heart rate, respiratory rate), cardiac function, hemodynamics, biochemical indexes, electrocardiogram, cardiac color Doppler ultrasound and adverse reactions were observed before and after treatment in the two groups. The incidence of cardiovascular events (worsening, re-hospitalization and death) was followed up 1 month after discharge. Results The left ventricular ejection fraction (LVEF), central venous pressure (CVP), arterial oxygen saturation (SaO2), arterial partial pressure of oxygen (PaO2), N-terminal B-type natriuria (NT-proBNP), lactic acid, serum creatinine (SCr), blood sodium and potassium of the two groups after treatment were not statistically significant compared with those before treatment [LVEF: the control group was 0.52±0.09 vs. 0.60±0.09, the observation group was 0.62±0.12 vs. 0.50±0.11;CVP (mmHg, 1 mmHg = 0.133 kPa): the control group was 11.2±2.8 vs. 13.0±2.9, the observation group was 13.0±2.5 vs. 10.5±3.6; SaO2: the control group was 0.98 (0.90, 0.99) vs. 0.99 (0.98, 1.00), the observation group was 0.95 (0.94, 0.98) vs. 0.96 (0.90, 1.00); PaO2(mmHg): the control group was 100.5 (63.8, 135.3) vs. 99.5 (82.3, 179.5), the observation group was 95.0 (85.5, 129.0) vs. 75.5 (59.0, 138.3); NT-proBNP (pg/L): the control group was 1.45 (1.34, 3.31) vs. 0.92 (0.42, 1.81), the observation group was 0.47 (0.35, 1.37) vs. 2.07 (1.27, 4.44); lactic acid (mmol/L): the control group was 3.6 (2.4, 4.5) vs. 1.4 (1.2, 3.1), the observation group was 1.3 (1.1, 2.1) vs. 3.1 (1.4, 3.7); SCr (μmol/L): the control group was 106.7±35.9 vs. 84.4±20.3, the observation group was 96.5±40.7 vs. 77.1±23.1; sodium (mmol/L):the control group was 141.4±7.2 vs. 143.6±4.2, the observation group was 142.9±3.6 vs. 140.5±4.5; potassium (mmol/L): the control group was 4.6±0.9 vs. 4.8±0.6, the observation group was 4.8±0.6 vs. 4.1±0.6, all P > 0.05];the comparisons between the following indicators in levels before and after treatment in the two groups had statistical significant differences: the peripheral arterial pressure (PAP), white blood cell count (WBC), hemoglobin (Hb), platelet count (PLT), alanine aminotransferas (ALT) and aspartate aminotransferase (AST) [PAP (mmHg): the control group was 33.0 (24.0, 59.3) vs. 38.0 (34.8, 46.0), the observation group was 30.0 (25.0, 32.0) vs. 53.5 (29.3, 66.5); WBC (×109/L):the control group was 12.2 (10.4, 13.9) vs. 5.7 (4.4, 8.6), the observation group was: 8.4 (3.7, 11.8) vs. 8.6 (5.7, 12.4); Hb (g/L): the control group was 95.6±12.9 vs. 130.3±15.0, the observation group was 111.1±22.6 vs. 112.4±24.6; PLT (×109/L): the control group was 95.2±21.3 vs. 168.7±32.6, the observation group was 146.3±68.1 vs. 132.7±45.1;ALT (U/L): the control group was 36.5 (15.3, 80.5) vs. 14.0 (11.0, 19.0), the observation group was 15.0 (10.0, 32.3) vs. 20.3 (12.0, 35.8); AST (U/L): the control group was 33.0 (20.0, 83.0) vs. 16.5 (16.7, 28.8), the observation group was 35.5 (12.3, 56.8) vs. 75.5 (45.3, 140.3), all P < 0.05]; after treatment, the urea nitrogen (BUN) level in control group was higher than that before treatment (mmol/L: 11.4±4.7 vs. 7.1±2.5), while BUN in the observation group was decreased (mmol/L: 6.5 ±3.3 vs. 9.1±3.8), there was statistical significant difference in BUN level between the two groups after treatment (P < 0.05). The levels of systolic blood pressure and respiratory rate after treatment in the two groups were significantly higher than those before treatment (all P < 0.05). After treatment, the diastolic blood pressure in the observation group was increased, but there was no significant difference in the control group before and after treatment, and the diastolic blood pressure in the observation group after treatment was higher than that in the control group (mmHg: 67.8±9.9 vs. 62.0±10.5, P < 0.05). According to the New York Heart Association Heart (NYHA) function efficacy assessment score, the total effective rate of the observation group was higher than that of the control group [93.7% (30/32) vs. 83.3% (25/30), P > 0.05]. There was no statistical significant difference in the incidence of adverse reactions between the observation group and the control group [12.5% (4/32) vs. 30.0% (9/30), P > 0.05]. The patients in the two groups were followed up for one month after discharge, 9 cases (30.0%) in the control group were re-hospitalized due to heart failure, and 3 cases (9.4%) in the observation group were re-hospitalized due to heart failure, there was no statistical significant difference between the two groups in re-hospitalization rate (P > 0.05). Conclusion Oprinone hydrochloride can effectively improve cardiac function and maintain hemodynamic stability of patients after heart valve replacement surgery.

4.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 721-724, 2017.
Article in Chinese | WPRIM | ID: wpr-665827

ABSTRACT

Objective To evaluate the short-term follow-up of valve-sparing aortic root replacement in Marfan syndrome. Methods 54 patients, 38 males and 16 females;aged(20-50) years, mean(31. 26 ± 7. 80) years old. They were all diag-nosed with Marfan syndrome according to the criteria of Ghent in 1996. Preoperative ultrasound showed 5 cases with trace aortic valve regurgitation, a small amount of reflux in 12 cases, 22 cases in the middle amount of regurgitation, 15 cases with a large number of reflux. According to the surgery program it was devided into 2 groups, Bentall group(35 cases, Bentall surgery) and David group(19 cases, David surgery). Follow-up 12 months to 48 months, to compare the differences of the efficacy of differ-ent surgical options,before and after surgery. Results 2 cases died after operation, one patient in group bentall died of uncon-trollable bleeding and the other in group David died of pulmonary infection, multiple organ failure, and the remaining 52 cases recoveredwell.GroupbentallwhichCPB(141.09±15.483)min,aorticocclusion(93.82±15.06)min. GroupDavid,CPB (186.32 ±23.96)min, aortic occlusion(140.21 ±22.13) min. There are significant differences in postoperative EF value, left ventricular diameter and postoperative left ventricular systolic volume ( ESV ) , postoperative left ventricular end-diastolic volume(EDV), FS improvement with preoperative data(P<0. 05), and there were no significant differences(P>0. 05) be-tween the two groups. The early postoperative complications were no significant difference between the tuo groups, bue the late complications in group bentall was significantly higher than groups David. Patients were followed up for 12 months to 48 months, one patient in David group underwent aortic valve replacement surgery because of severe aortic regurgitation. One case ( abdominal aorta) in group Bentall underwent surgery due to recurrent dissection and 6 cases with bleeding, embolic complica-tions because of warfarin. Conclusion Valve sparing root replacement has provided satisfactory short-term outcomes for Marfan syndrome.

5.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12): 245-246, 2016.
Article in Chinese | WPRIM | ID: wpr-489048
6.
Pakistan Journal of Pharmaceutical Sciences. 2014; 27 (6): 2095-2099
in English | IMEMR | ID: emr-153273

ABSTRACT

The authors model diabetes in rats, and inject the rats with Klotho gene. Then the levels of serum lipoprotein are tested, measuring the thickness of coronary artery intima and the ratio of intima and media to see whether Klotho gene has protective effect of coronary artery in diabetes rats. Extracting the Klotho gene from kidney tissue in the normal SD rats amplifies the target gene by PCR and uses adenovirus as carrier. Then SD rats were randomly divided into model group, control group and the treatment group for diabetes modeling. Transferred the Klotho gene into treatment group and blank adenovirus into control group by the experimenters. Nothing was done for model group. Rats were killed after a successful modeling in the twelfth week, then tested blood low-density lipoprotein, high density lipoprotein, and the coronary artery intima-media thickness. After doing these, intima-media thickness ratio was tested. The high density lipoprotein is 0.67 +/- 0.06 mmol/L in treatment group, 0.48 +/- 0.10mmol/L in control group, 0.47 +/- 0.10mmol/L in model group. The treatment group, control group and model group respectively two independent sample tests. There is statistical significance between treatment group and the other group p<0.01 in treatment group. The low density lipoprotein is 0.44 +/- 0.08 mmol/L in treatment group, 0.45 +/- 0.10mmol/L in control group, 0.44 +/- 0.05mmol/L in model group. Respectively two independent sample test show that there is no statistical significance between treatment group and the other group [p<0.05]. Intima thickness is 1.74 +/- 0.05 micro m in treatment group, 2.23 +/- 0.06 micro m in control group, 2.15 +/- 0.05 micro m in model group. There is statistical significance between treatment group and the other group [p<0.01]. The ratio of intima and media is 0.237 +/- 0.097 in treatment group, 0.308 +/- 0.023 in control group, 0.316 +/- 0.037 in model group, and t test, there is statistical significance between treatment group and the other group [p<0.01]. There is protective effect on coronary after Klotho gene was transferred into diabetic rats

7.
Chinese Journal of Medical Education Research ; (12): 915-918, 2012.
Article in Chinese | WPRIM | ID: wpr-420422

ABSTRACT

Objective To explore the effect of applying problem-based learning (PBL) combined with ' pre-resident physician' teaching model in clinical practice in the nephrology department.Methods Sixty students in clinical practice were divided into two groups:experimental group and control group.The students in experimental group were received PBL in combination with 'pre-resident physician' teaching model while those in control group were received traditional teaching model.The effect was evaluated according to the results of theoretic examination and investigation.The results were analyzed by x2 test and P < 0.05 signified statistically significant.Results The average score of theoretic examination in experimental group was 80.22 while that in control group was 76.53.The students in experimental group had significant higher score than those in control group (P < 0.05 ).The overall satisfaction degree was 93.00% in experimental group concerning the 8 indicators in PBL combined 'pre-resident physician' teaching model,while that was 73.75 % in control group concerning the 8 indicators in traditional teaching mode.Concerning the aspects of teaching flexibility,arousing learning interest,training literature capacity and improving ability of independent problem solving,the satisfaction degree was higher in experimental group than in control group (P < 0.05 ).Conclusion PBL in combination with ' pre-resident physician' teaching model has evident advantages in clinical practice in nephrology department.

8.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 72-4, 2007.
Article in English | WPRIM | ID: wpr-634502

ABSTRACT

To investigate the mechanism and correlated factors of systolic anterior motion (SAM) phenomenon after aortic valve replacement, 48 patients with severe aortic valvular stenosis were studied. Tested by echo-Doppler one week after aortic valve replacement, the patients were divided into two groups: SAM group and non-SAM group. The data of the left ventricular end-diastolic diameters, the left ventricular end-systolic diameters, the left ventricular outflow diameters, the thickness of the interventricular septum, the posterior wall of left ventricle, the blood velocities of left ventricular outflow and intra-cavitary gradients were recorded and compared. The results showed that no patients died during or after the operation. The blood velocities of left ventricular outflow was increased significantly in 9 patients (>2.5 m/s), and 6 of them developed SAM phenomenon. There was significant difference in all indexes (P0.05) between two groups. These indicated that the present of SAM phenomenon after aortic valve replacement may be directly related to the increase of blood velocities of left ventricular outflow and intra-cavitary gradients. It is also suggested that smaller left ventricular diastolic diameters, left ventricular systolic diameters, left ventricular outflow diameters and hypertrophy of interventricular septum may be the anatomy basis of SAM phenomenon.

9.
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 72-74, 2007.
Article in Chinese | WPRIM | ID: wpr-317484

ABSTRACT

To investigate the mechanism and correlated factors of systolic anterior motion (SAM) phenomenon after aortic valve replacement, 48 patients with severe aortic valvular stenosis were studied. Tested by echo-Doppler one week after aortic valve replacement, the patients were divided into two groups: SAM group and non-SAM group. The data of the left ventricular end-diastolic diameters, the left ventricular end-systolic diameters, the left ventricular outflow diameters, the thickness of the interventricular septum, the posterior wall of left ventricle, the blood velocities of left ventricular outflow and intra-cavitary gradients were recorded and compared. The results showed that no patients died during or after the operation. The blood velocities of left ventricular outflow was increased significantly in 9 patients (>2.5 m/s), and 6 of them developed SAM phenomenon. There was significant difference in all indexes (P<0.05 or P<0.01) except the posterior wall of left ventricle (P>0.05) between two groups. These indicated that the present of SAM phenomenon after aortic valve replacement may be directly related to the increase of blood velocities of left ventricular outflow and intra-cavitary gradients. It is also suggested that smaller left ventricular diastolic diameters, left ventricular systolic diameters, left ventricular outflow diameters and hypertrophy of interventricular septum may be the anatomy basis of SAM phenomenon.

10.
Chinese Journal of Thoracic and Cardiovascular Surgery ; (12)2003.
Article in Chinese | WPRIM | ID: wpr-571621

ABSTRACT

Objective: To investigate the mechanism and correlative factors of SAM syndrome after aortic valve replacement. Methods: 48 patients with severe aortic valve stenosis were studied, echo-Doppler study was performed one week after aortic valve replacement, and the patients were divided into two groups with or without SAM Syndrome. The left ventricular end-diastolic dimensions, the left ventricular end-Systolic dimensions, the left ventricular outflow tract the thickness of septum and posterior wall, the maximal left ventricular velocities and left intra-ventricular dynamic gradients were recorded and compared. Results: There was no operative mortality. The maximal left ventricular velocities were increased significantly in 9 patients (more than 2。5 m/s) and six of them had SAM syndrome. There were statistic significance (P

SELECTION OF CITATIONS
SEARCH DETAIL